Fangkuai LPG boiler series adopts a more environmentally friendly combustion method – full premixed combustion, fully premixed fuel and air, so that the gas and air are completely mixed, and the fuel burns more fully. At the same time, it can increase the heat load of the furnace volume, and reduce the formation of high-temperature NOx. LPG combi boilers work similarly to natural gas boilers, where a burner heats water in a heat exchanger, and the heated water is then circulated around the home through a network of pipes and radiators. The main difference is that LPG is stored in a tank outside the home, which is then connected to the boiler via a pipeline. Boilers are very suitable for low-temperature heating systems, solving the problems of low load and low-temperature corrosion in hot water boiler systems.
The integration of complete condensation technology makes the boiler operating efficiency increase by more than 10%, as high as 104%, which is the first choice for energy-saving heating.
Full-premixed combustion technology controls nitrogen oxide emissions from the source of combustion, making the use of clean energy cleaner and more environmentally friendly.
In the lpg water boiler package design, users only need to install water inlet and outlet pipes, chimneys, gas pipes, and power on-site to start the boiler.
The boiler has a complete safety protection function. If there is a sudden failure, it can immediately call the police to protect the safety of the boiler operation in all directions.
The combustion system adopts the internationally advanced fully premixed burner, and the fuel and the combustion-supporting gas are fully and uniformly mixed before entering the combustion chamber to make the combustion more complete; increase the heat load of the furnace volume and reduce the production of high-temperature nitrogen oxides (NOx), The thermal efficiency of the boiler can reach as high as 104%.
The heating surface at the low-temperature end adopts Fangkuai’s unique Ultraten technology—feather tubes. The heat exchange area is more than 5 times that of ordinary light tubes, which can replace more heat in the flue gas and greatly reduce the smoke exhaust of the boiler. temperature, increase the flue gas condensation rate and greatly improve the boiler efficiency.
Types | Rated Thermal Power | Rated steam pressure | Thermal efficiency | Fuel | Power requirement | Length * Width * Height | Weight | Chimney |
---|---|---|---|---|---|---|---|---|
Unit | Mw | MPa | % | V/Hz | mm | t | mm | |
H6-700 | 0.7 | 0.1 | 97.2-106% | Natural gas | 220/50 | 1960 * 1000 * 1860 | 1.86 | 250 |
H6-1400 | 1.4 | 3595 * 1325 * 2750 | 4.4 | 300 | ||||
H6-2800 | 2.8 | 4205 * 1950 * 3380 | 6.9 | 450 |
Contact us for more details about our